Time limit is exhausted. Please reload CAPTCHA. 1 × 6 =
CANTY specializes in Mud Flow Analysis as well as Drilling Mud PSA.
Name
Email address
Phone
Inquiry
Features:
• Volume Flow Analysis
• Fluid Front Detection
• Real-Time Viewing
The CANTY SolidSizer™ is a vision-based sensor used with the CANTY Vector System image processor for dry sand size measurement in a laboratory environment. The CantyVision™ Software accurately measures multiple aspects of the sand from area / perimeter / minor and major axis / etc. In comparison to a sieve which measures only minor axis the CantyVision™ software can correlate directly to a sieve so the customer does not have to change any QC documents. The SolidSizer™ can correlate within 2% of a sieve. A typical sieve analysis takes anywhere from 20-30 minutes including cleaning and setup for a 70-100 gram sample. On the SolidSizer™ that same sample takes less than 2 minutes. Also multiple screen distributions can be setup to accommodate multiple customers or areas in the process, hence eliminating the need for multiple runs on the same sand for different size distributions. After correlating to current methods of minor axis, customers find benefit in comparing minor axis to major axis and making sure the sand is round instead of needle shaped. Reduce lab time and make sure production samples are not skipped over due to lack of sample time available!
• Inline Particle size down to 1µm
• Analysis of oil or water based mud
• Detect oil / water / solids / gas
• Lab Particle size down to 1µm
CANTY manufactures high temperature camera systems that are used to measure the temperature of materials 1,000°F and higher. In this temperature range, most materials emit light in the visible spectrum due to blackbody radiation that is able to be measured to determine temperature on a visible spectrum imaging system. This allows Canty to measure temperature in applications including tube metal, refractory, metal sheets/slabs, etc…
CANTY specializes in WATER IN OIL monitoring. CANTY can detecting the water droplet size as well as concentration independent of solids or gas.
The CANTY Inflow™ is a vision-based camera system used with the CANTY Vector System image processor for OiW & WiO concentration and size measurement in-line: the crude inlet, crude outlet, & effluent water. The CantyVision™ Software accurately measures multiple aspects of the OiW & WiO from oil / water / solids / gas independent of each other for accurate data. In comparison to a florescence monitor, which measures only oil and is affected by solids and gas in the stream. The CantyVision™ software can identify the differences and the customer can visually verify the readings. The Inflow™ can calibrated with the customers current lab method to make for easy instillation in the field. Determining PPM on the inlet will help optimize the desalter intake and verify what is entering the unit. Providing PPM on the outlets the desalter will benefit the effluent water side for EPA regulations as well as the crude side to increase production efficiency. The interface can be controlled through automaic sampling, instead of having to take sample test bottles. Video recording is an option for later analysis. In-line analysis makes sure production samples are not skipped over due to lack of time!
The CANTY Ultratemp™ is a vision-based camera system used with the CANTY Vector System image processor to monitor temperature of the tubes inside a hydrogen reformer. The CantyVision™ Software accurately measures temperature as well as bend in the tube for complete control. In comparison to thermocouples which are costly, not reliable, and monitor only one tube, a camera system can monitor multiple tubes at the same time. The CantyVision™ software can output a signal to alarm if the tube has increased in temperature over a certain time to an operator screen, PLC, or DCS for closed loop control. The steam can then be introduced to clean the tube and avoid plugging and then switch back to the natural gas. The pyrometer is not effective for controlling the temperature in the reformer due to the time intervals in between analysis is taken. Also, not everyone measures at the same point and this could lead to a change in temperature when a change never occurred. To calibrate the system the pyrometer can be used initially. If the temperature in the tubes increase over 10°C over 10 min, a plug has a chance to take place. With the Ultratemp™ this event can be avoided completely.